-40%

NEW ECG Machine 1212G Digital Touch 12 Channel EKG Electrocardiograph Printer CE

$ 316.27

Availability: 10 in stock
  • ECG & EKG Machine Type: Electrocardiograph
  • Features: Printer
  • Condition: New
  • Bundle Listing: Yes
  • Item must be returned within: 60 Days
  • Number of Leads: 12
  • Refund will be given as: Money Back
  • Model: ECG1212G
  • Restocking Fee: No
  • All returns accepted: Returns Accepted
  • Return shipping will be paid by: Buyer
  • Mounting: Cart Mounted
  • Operation mode: touch screen and function keys
  • Screen: 10.1'' color LCD
  • Operation: Digital
  • Number of Channels: 12
  • MPN: 69450401
  • Brand: CONTEC

    Description

    ECG1212G Electrocardiograph
    Digital 12 channel/lead, Touch Screen, USB PC Software
    Description
    Introduction
    The device is an electrocardiograph which can collect 12-lead ECG signal simultaneously and print ECG waveform with thermal printing system. It features in, recording and displaying ECG waveform in auto / manual mode; measuring, analyzing and diagnosing ECG waveform parameters automatically; prompting for “Lead off” and “Lack of paper”; optional interface language (Chinese / English, etc.); built-in lithium battery, AC / DC; selecting rhythm lead freely to observe abnormal heart rhythm; case database management.
    Functions
    1)Adopt 10.1'' high-resolution color LCD, operate by full-touch screen and function bu ttons, convenient to use.
    2)Sync collection for 12-lead ECG, support 12-lead and Cabrera-lead waveform display. Get high-quality ECG waveform via power frequency filter (50 / 60 Hz), baseline filter and EMG filter (25 / 35 Hz) of ECG signal.
    3)Display 3 / 6 / 12 - lead ECG waveform, HR value, print mode, sensitivity, paper speed, filter state, clock, battery power, background grid, measured parameter and interpretation, etc. on one screen, and with prompt functions for lead - off, overload and system working state.
    4)Power supply: AC / DC (which can adapt AC 50 / 60Hz), with built-in rechargeable lithium battery, charging circuit, perfect over-current and over-voltage protection circuit.
    5)In optimal DC state, up to 10-hour standby time, continuous print for more than 3-hour, which meets the requirements of visiting a patient at home and body examination.
    6)Built-in thermal printer, support multiple printing modes and formats, such as, auto M × N, M × N + 1, M × N + 2, rhythm M line and manual, etc. The contents including time, paper speed, sensitivity, calibration signal, lead name, filter state and patient information can be printed. The waveform length printed, measurement parameter output, diagnosis conclusion, superimposed QRS waveform, histogram, trend chart and interval list, etc. can be set. With the print functions (timing print and auto-print for arrhythmia, etc.), which meet different requirements.
    7)With the functions of auto-measurement and auto-interpretation for routine ECG parameters, provide measured results and auto-diagnosis conclusions for HR, PR interval, P Duration, QRS Duration, QT / QTc interval, P / QRS / T Axis, R (V5), S (V1), R (V5) + S (V1) amplitude, etc. which reduces the doctor’s burden.
    8)Built-in memory stores 4000 cases (data saving time: 10 s) at least, convenient for case review and statistic.
    9)Historical cases can be reviewed, inquired, modified, transmitted, printed, lead corrected, the cases can also be exported to other electronic file formats (dat, pdf, xml, bmp, jpeg, etc.)
    10)Chinese / English operating interface, the report in corresponding language can be printed; built-in virtual keyboard, support Chinese / English input method.
    11)Support external USB standard keyboard, mouse, scanner and printer.
    Performance
    1)Input mode: floating and defibrillation protection
    2)Lead: standard 12-lead
    3)Patient leak current: < 10 µA
    4)Input impedance: ≥ 2.5 MΩ
    5)Frequency response:
    Nominal input amplitude    Input frequency and waveform    Relative output response
    1.0    0.67 Hz ~ 40 Hz, sinusoidal    ±10 %a
    0.5    40 Hz ~ 100 Hz, sinusoidal    +10 %, -30 %a
    0.25    100 Hz ~ 150 Hz, sinusoidal    +10 %, -30 %a
    0.5    150 Hz ~ 500 Hz, sinusoidal    +10 %, -100 %a
    1.5    ≤1 Hz ,200 ms, triangular    +0 %, -10 %b
    a relative to 10 Hz output   b relative to 200 ms output
    6)Time constant: ≥ 3.2 s
    7)CMRR: > 105 dB
    8)Filter: power frequency (AC 50 / 60 Hz), EMG (25 Hz / 35 Hz (-3 dB)) and baseline drift
    9)Recording mode: thermal printing system
    10)Paper size: 210 mm (W) × 20 m (L), high-speed thermal paper
    11)Paper speed: 12.5 mm/s, 25 mm/s, 50 mm/s, error: ± 5 %
    12)Gain (sensitivity): 5, 10, 20 mm / mV, accuracy: ± 2 %
    Standard sensitivity: 10 mm/mV ± 0.2 mm/mV
    13)Record mode: auto, rhythm and manual record
    14)Measurement parameters: HR, P - R interval, P Duration, QRS Duration, T Duration, Q - T interval, Q - Tc, P Axis, QRS Axis, T Axis, R (V5) amplitude, S (V1) amplitude, R (V5) + S (V1) amplitude
    15)Safety class: class I, defibrillation-proof type CF applied part
    16)Polarizing voltage: ± 610 mV
    17)Noise level: ≤ 12 µVp-p
    18)Sampling frequency for ECG signal input: 32 kHz
    19)Sampling frequency for waveform data processing: 1 kHz
    20)Sampling accuracy: 24 - bit
    21)Minimum detection signal: a 10 Hz, 20 µV (peak - peak value) sinusoidal signal can yield a visual recorded deflection.
    22)Pacemaker detection channel: II
    23)Accuracy of input signal reproduction: ± 5 %
    24)Amplitude quantization: ≤ 5µV/LSB
    25)Time deviation in each channel: <100 µs
    26)Power supply:
    AC: 100V ~ 240V (50 / 60 Hz)
    DC: 14.8 V / 5200 mAh rechargeable lithium battery
    27)Degree of protection against ingress of liquid: IPX0
    28)Working mode: continuous operation
    Accessories
    Standard:
    One lead cable
    One limb electrode
    One chest electrode
    One thermal recording paper
    One power cord
    One earth wire
    One User Manual
    Physical characteristic
    Operating:
    a) Environment temperature: 5 ℃ ~ 40 ℃
    b) Relative humidity: 25 % ~ 95 % (non - condensing)
    c) Atmospheric pressure: 700 hPa ~ 1060 hPa
    Transport and storage:
    a) Environment temperature: - 20 ℃ ~ + 55 ℃
    b) Relative humidity: ≤ 95 %
    c) Atmospheric pressure: 500 hPa ~ 1060 hPa
    Dimension: 340 mm (L) × 320 mm (W) × 86 mm (H)
    Weight: 5 kg
    Buy safe products
    The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies.  If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.
    The machine is registered on the Australian Register of Therapeutic Goods(ARTG) with the code 197923,
    and certified by FDA of United States and CE,TUV of Europe. The  Fingertip Pulse Oximeter that is FDA 510K Approved.
    Payment
    We accept payment by PayPal. PayPal enables you to make payment quickly and securely online.
    1: We accept payment via PayPal.
    2: Please pay the money within 5 days after the auction ended.
    3: Please offer home or mobile phone when the item's Value exceeds 100 (USD, EUR, AUD, GBP) so that we can
    make sure you get the item safely.
    Shipping
    1. Items are dispatched with in 48 hours after payment receiced or eCheck cleared.
    2.Please make sure the address and tel number are right,both of the information  is very important for delivery,thank you for your kindly cooperation.
    3.After the shipment,we will add the tracking number on both ebay and paypal  website,you can check it and track it by the number.
    4. Usually we ship this item from China by air small package,it takes about 10-45 days arrive,and we will supply a tracking number to check its state online.
    Terms of Sale
    1. All items are brand new, with 2 years warranty.
    2.Client is reaponsible for the custom cleatance and custom duty.
    If any, we will not be responisble for the customs clearance and duty, if you have special requirments for the declaration for your customs office, please contact us before your payment.
    3. Customer is responsible for the returning shipping fee and we will send the replacement after receiving the returned item.
    4.  Your positive feedback will be appreciated very much,  and in any case, please do contact us before leaving nagative feedback or ship the item back, we promise we will give you a satisfied answer.
    About Us
    Contec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 1992
    as a high-tech company.
    At present there are more than 1200 employees in our company.Our product line covers a wide range of 13 categories.
    Most of the domestic hospitals are our customers.
    Contec hopes to cooperate with international companies to supply more innovative design and advanced technology products
    We sincerely welcome you to become one of our global partners.We are looking forward to establishing a successful business relationship with you.
    Contact Us
    Contec Medical Systems-Jane
    Powered by SoldEazy
    We only have the English Manual in the standard package, If you need any other language Manual, please contact us freely