-40%

CONTEC ECG300G Digital 3 Channel 12 lead Electrocardiograph EKG Machine+ PC SW

$ 189.55

Availability: 145 in stock
  • Item must be returned within: 60 Days
  • Brand: CONTEC
  • Operation: Digital
  • Number of Channels: 3
  • ECG & EKG Machine Type: Electrocardiograph
  • Country/Region of Manufacture: China
  • Return shipping will be paid by: Buyer
  • Condition: New
  • Restocking Fee: No
  • Number of Leads: 12 Leads
  • Refund will be given as: Money Back
  • MPN: 69450401
  • Bundle Listing: Yes
  • Application: Resting
  • All returns accepted: Returns Accepted
  • Model: ECG300G
  • Features: Printer

    Description

    ECG300G Electrocardiograph
    3 channel 12 lead, usb pc software
    Description
    Introduction
    ECG300G is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, selecting any rhythm lead, case database management.
    Function
    1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
    2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
    3)Multiply printing modes and formats, including manual, auto 4×3, auto 3×4+1, auto 3×4, auto 2×6+1, auto 2×6, auto 3-2+1, auto 3-2, auto 1×12+1, auto 1×12, rhythm 4, rhythm 3 and rhythm 2, etc. Waveform length printed can be adjusted, and with time print function, which meets different requirements.
    4)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
    5)Built-in memory stores up to 1000 cases, convenient for case review and statistic.
    6)Multi-language(Chinese, English, Spanish, Turkish, Polish, Italian, French, German, Portuguese, Kazakstan, Russian, Ukrainian, Serbian and Slovenian) interface and report.
    Performance
    Input mode: floating and defibrillation protection
    Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
    CMRR: >60dB, >100dB(add filter)
    Time constant:≥ 3.2s
    Patient leak current: <10µA
    Calibration voltage: 1mV
    Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
    Noise level: <15µVp-p
    Input circuit current: ≤50nA
    Input impedance: ≥50MΩ
    Sampling accuracy: 12-bit
    Safety classification: class I, type CF and defibrillation-proof applied part
    Recording mode: thermal printing system
    Auto record: set record according to auto record format and mode, automatically switching leads, measuring and analyzing.
    Rhythm record: set record according to rhythm record format and mode, automatically measuring and analyzing.
    Manual record: set record according to record format, manually switching leads.
    Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
    Paper size: 80mm(W)×20m(L)
    Sampling frequency: 1000Hz
    EMG interference filter: 25Hz/35Hz (-3dB)
    Power frequency filter: AC 50Hz/60Hz(-20dB)
    Paper speed:
    Auto: 25, 50mm/s, ±5%
    Rhythm: 25, 50mm/s, ±5%
    Manual: 5, 6.25, 10, 12.5, 25, 50mm/s, ±5%
    Power supply:
    AC: 100V~240V(50/60Hz)
    DC: 7.4V/3500mAh rechargeable lithium battery
    Fuse specification: two AC time lag fuse(φ5×20mm), T1.6AL250V
    Waterproof degree: IPX0
    Working mode: continuous working
    Accessories
    Standard:
    A lead cable
    A limb electrode
    A chest electrode
    A thermal recording paper
    A power cord
    An earth wire
    A user manual
    ECG-Sync software+USB cable
    Optional:
    ECG electrode
    Bag
    Conductive gel
    Physical characteristic
    Working environment
    Temperature: 5℃~40℃
    Relative humidity: 25%~95%(non-condensing)
    Atmospheric pressure: 700hPa~1060hPa
    Transport and storage environment
    Temperature: -40℃~+55℃
    Relative humidity: ≤95%
    Atmospheric pressure: 500hPa~1060hPa
    Dimension: 315mm(L) × 215mm(W) × 77mm(H)
    Weigh: 1.6Kg
    Buy Safe Product!
    The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.
    The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and CE &TUV of Europe.
    Payment
    We accept payment by PayPal. PayPal enables you to make payment quickly and securely online.
    1: We accept payment via PayPal.
    2: Please pay the money within 5 days after the auction ended.
    3: Please offer home or mobile phone when the item's Value exceeds 100 (USD, EUR, AUD, GBP) so that we can
    make sure you get the item safely.
    Shipping
    1). We will ship within 2 business day after your payement ;
    We ship the item by USPS first class service for USA buyers,you can get the item in 1-5 days.
    2).We don't add taxes, VAT or other hidden charges. You pay us what you see on the invoice, i.e. goods subtotal + shipping cost (not include duties).
    Please find out as much as you can about your import taxes in your own country before bidding the item. You need to pay for the import duties in case that occurred for certain goods, or you may kindly give us some suggestions about that, we promise to do our best to help you!
    Terms of Sale
    About Warranty:
    We guarantees new equipment other than accessories to be free from defects in workmanship and materials for a period of twelve months (six months for spare parts) from the date of shipment under normal use and service. Our company's obligation under this warranty is limited to repairing, at our company's option, any part which upon our company's examination proves defective.
    Return Policy:
    If you receive a defective item which you want to return, please contact us within 5 days from the day you receive the item.
    All return items must be returned with its original packaging and accessories. If we confirm the damage happened during the shipment, we will bear the shipping cost for return.
    We will refund the money to you when we get the return items. Or replace item for you free of charge.
    About Us
    Contec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 1992
    as a high-tech company.
    At present there are more than 1200 employees in our company.Our product line covers a wide range of 13 categories.
    Most of the domestic hospitals are our customers.
    Contec hopes to cooperate with international companies to supply more innovative design and advanced technology products
    We sincerely welcome you to become one of our global partners.We are looking forward to establishing a successful business relationship with you.
    If you have any questions or Dissatisfaction, please contact us via ebay message, we will try our best to help you to solve the problem and give you satisfied answer
    Contact Us
    Contec Medical Systems
    Contact name: Yoki
    Contec Medical Systems Co.,Ltd; 20 Years manufacturer,we have stock in USA and China.
    Powered by SoldEazy
    We only have the English Manual in the standard package, If you need any other language Manual, please contact us freely